In some cases it may be necessary to perform a Clear All procedure and reset all of the program settings back to the factory default. This is usually done by a factory trained technician that is upgrading software, transferring a board from unit to unit, or if a memory clear is needed. It is recommended that you save a configuration file of the current program settings or copy all of the settings to a notepad before performing a clear all if you plan to preprogram the unit with the same information.
Follow these steps to perform a clear all:
1.Enter the calibration mode by loosening the calibration bolt on the side of the Register until the Main Menu is displayed on the screen.
2.Navigate to the Setup Menu and press OK.
3.Navigate to the Security option and press OK.
4.Navigate to Reset Register Fields option and press OK.
5.Select Clear All from the list box that is displayed and press OK.
6.A prompt will appear: “Are you sure you want to clear all settings? All settings will revert back to factory defaults including custom settings.”
7.To proceed with the clear all, press the Yes function key and the clear all process will begin.
8.Once complete, all programmable fields (except Time and Date) will be reset to factory default settings.
9.Reprogram the unit as appropriate.