After installing the ground kits, use a multimeter to confirm that the seat and printer are both grounded properly.
Follow these steps to verify a good ground connection:
1.Turn OFF all accessories, including the dome light, to prevent other currents from distorting the reading.
2.Take a multimeter and measure the resistance between the brackets the two ground strap bolts are fastened to. Find a clean spot on the brackets without paint to use as contact points. Other bolts on the brackets are often suitable.
Turn Off Accessories |
If the multimeter reads “MΩ” or “KΩ”, typically, one of the accessories is still on |
•If the resistance is less than 3Ω, the system is grounded adequately.
•If the resistance is still greater than 3Ω, check for proper metal to metal contact on both ends of the ground strap. Clean any paint, dirt, or oxidation that may block the grounding point. If the resistance remains above 3Ω, attach the ground strap to a different ground point. Repeat the process until the ground resistance is below 3Ω.
Verify good contact |
If operator receives a ESD discharge when leaving the seat, the ground strap is not installed correctly. |