<< Click to Display Table of Contents >> Navigation: LCR.iQ Product Manual > Specifications |
The Register housing and bases are aluminum castings that are powder-coated with high durability, urethane powder. The cover internal hinge design provides easy access to the internal connections and keeps all moving hinge parts out of the elements to further prevent corrosion. Weights and Measures features are accessible by using a seal-able fastener on the side of the cover.
•High grade A360 Die Cast Aluminum, enclosure cover, and enclosure base
•Chromate finish with powder-coat protective coating
•Tempered glass display window
•Silicone display glass seal
•Stainless steel display bracket
•Silicone door seal
•Keypad – Membrane Switch with silicone overlay
•Stainless steel fasteners/hardware
•Stainless steel bonded silicone sealing washer
•The Register is certified for normal operation within the temperature range of -40 to 140 °F (-40 to 60 °C).
•7 inch heavy duty, high definition TFT/LCD (Thin Film Transistor Liquid Crystal Display) video display with LED backlight unit.
•800 x 480 pixels (152.4 mm x 91.4 mm)
•Luminance: 1500 (cd/m2)
•Display acceptable operation or storage temperature -40 °F to 185 °F (-40 °C to 85 °C).
•Approximately 14 lbs / 6.5 kgs (no added accessories)
•Ten (10), 1/2-inch NPT (1/2-14 NPT) threaded ports
The Register alphanumeric keypad is made of petroleum resistant silicone and consists of 12 large alpha-numeric keys, 5 navigation keys, and 5 function keys that relate to the adjacent display indicators for operator-guided functionality. The keys, when pressed, give the operator a tactile, positive confirmation of keystrokes. The keypad multi-tap functionality also allows users to input up to four alpha-numeric characters on a single key.
Inputs are configurable in the Register to handle a variety of external accessories that provide data signals in the metering system including pulse input and a variety of external sensors.
Register Input Voltage
•Voltage – 9 to 28 VDC
•Current maximum: 5 A maximum
Pulse Input
In order to calculate flow measurements when mounted to a positive displacement meter, the Register receives a pulse input from a quadrature pulser that is mechanically connected to the flow meter output shaft (meter mount option only). A pulse input can also come from an external device such as a Liquid Controls Pulse Output Device (POD) or another externally mounted pulse generator. If an external LC POD is purchased, these materials are necessary, but are not supplied with the POD:
•16-22 AWG 4 conductor Shielded Cable (Consult the POD manual for complete specifications)
•Weather Proof flexible conduit or loom
•½” Conduit connectors or cable glands
RTD Temperature Probe
The Register is equipped with an input for a temperature probe, so the register can read realtime temperature as well as compensate volume measurements according to the temperature of the product.
•4 wire platinum sensor
•100 Ω resistance at 0 ºC
•138.5 Ω resistance at 100 ºC
Optical Air Eliminator
The Register is equipped to handle an optical air eliminator input:
•Voltage – 10 to 28 VDC
•Current – 0.5 Amp maximum
Digital Inputs 1, 2, 3, 4, 5, and 6
•Active Low, normally pulled high
•Voltage: 5 to 28 VDC
•Current: 3 mA maximum sink current
•Maximum Frequency: 10 kHz
The Register is equipped with six digital outputs and four solenoid outputs. These outputs allow the Register to communicate with meter system accessories such as solenoid- controlled valves, optical air and vapor eliminators, remote displays, printers, and third-party devices.
Digital Outputs 1, 2, 3, 4, 5, and 6
•Open drain output, active low to ground, thermally protected
•Voltage: 5 to 28 VDC
•Current: 500 mA maximum
Outputs for solenoids 1, 2, 3, and 4
•Open drain output, active low to ground, thermally protected
•Voltage: 12 VDC nominal
•Current: 1 A maximum
•Voltage: 24 VDC nominal
•Current: 0.5 A maximum
Pulse Output
•Voltage peak to peak – 5 to 28 V
•Frequency maximum – 7500 Hz
Scale Pulse Output
•Current sinking capability: 150 mA
Electrical Protection
•5 A fuse on power cable
•RS-232
•RS-485
•CAN BUS – Consult the applicable Chassis Builder’s Guide, available from the truck chassis manufacturer.
•Ethernet (Gigabit)
•Bluetooth (wireless)
•Wi-Fi (wireless)
•Voltage – 24 VDC
•Current – 0.8 Amp maximum
•Operating Temperature – -22 to 104 ºF (-30 to 40 ºC)